Home » Products » Fiber » Cable » CPR Cables » Tight Buffered Distribution Fibre Optic Cable CPR
Tight buffered (TB) universal distribution (DB) cables are constructed of 900µm tight buffered fibers surrounded by waterblocking e-glass strength members jacketed in an LSZH outer jacket. Euroclass Dca-s1,d1,a1
DESCRIPTION | 4-CORE | 8-CORE | 12-CORE | 24-CORE | |
---|---|---|---|---|---|
Outer Diameter | mm | 5.4 ± 0.3 | 5.9 ± 0.3 | 7.6 ± 0.3 | 9.6 ± 0.3 |
Weight | kg/km | 26 | 32 | 45 | 65 |
Maximum Tensile Load (installation) | N | 400 | 400 | 450 | 650 |
Cable water blocking | pass | pass | pass | pass | |
Minimum Bend Radius (installation) | mm | 108 | 118 | 152 | 192 |
Minimum Bend Radius (installed) | mm | 54 | 59 | 76 | 96 |
Fire Performance (EN50575) | Euroclass |
Dca-s1,d1,a1
|
|||
Operating Temperature | °C | -20~+60 | -20~+60 | -20~+60 | -20~+60 |
Storage Temperature | °C | -20~+60 | -20~+60 | -20~+60 | -20~+60 |
Installation Temperature | °C | -5~+60 | -5~+50 | -5~+50 | -5~+50 |
Crush Resistance (Short term) | N/100 mm | 500 | 500 | 500 | 500 |
Fire Test Parameter | Test Method | Result | |||
Reaction to Fire | IEC 60332-1
IEC 60332-3-24 EN 50575 |
EuroClass Dca-s1,d1,a1 |
|||
Smoke Density | IEC 61034-2 | ||||
Halogen acid gas content | IEC 60754-1 | Zero | |||
Degree of acidity of gases | IEC 60754-2 | Minimum 4.3 pH
Maximum 10 µS/mm |
PART NUMBER (PN) |
DESCRIPTION | PHASING OUT PN |
---|---|---|
C1BE*F8AFL | AFL **f OM1 62.5/125 I/E DB Cable TB 900µm E-Glass LSZH Black CPR | OM1TB**UCBK |
C2BE*F8AFL | AFL **f OM2 50/125 I/E DB Cable TB 900µm E-Glass LSZH Black CPR | OM2TB**UCBK |
C3BE*F8AFL | AFL **f OM3 50/125 I/E DB Cable TB 900µm E-Glass LSZH Black CPR | OM3TB**UCBK |
C4BE*F8AFL | AFL **f OM4 50/125 I/E DB Cable TB 900µm E-Glass LSZH Black CPR | OM4TB**UCBK |
C7BE*F8AFL | AFL **f G.657A1 9/125 I/E DB Cable TB 900µm E-Glass LSZH Black CPR | OS1TB**UCBK |
C8BE*F8AFL | AFL **f G.657A2 9/125 I/E DB Cable TB 900µm E-Glass LSZH Black CPR | 7A2TB**UCBK |
Where * is the cable fiber count code for the part number and ** is the cable fiber count for the description
The following table represents colors available, on request, for the cable jacket.***Please note that these colors are for guidance only and may display differently depending on your screen or printer.
To order a four fiber single mode cable with red jacket replace F8 in the part number with F7 and change Black in the description to Red.
For example – C7BE4F7AFL – AFL 04f G.657A1 I/E DB Cable TB 900µm E-Glass LSZH Red CPR
*Fiber count code | ** Cable fiber count |
---|---|
4 | 04 |
6 | 06 |
8 | 08 |
A | 12 |
B | 16 |
C | 24 |
Color name | Blue | Orange | Red | Black | Yellow | Purple | Aqua |
---|---|---|---|---|---|---|---|
Color Code | 1 | 2 | 7 | 8 | 9 | A | C |
***Color |