Breakout cables are constructed of up to 24, 2mm simplex cables stranded around a central strength member. Each simplex cable has its own aramid yarn strength member and jacket. These sub units are wrapped in a polyester tape and jacketed in LSZH material. EuroClass Eca
DESCRIPTION | UNITS | 4 ELEMENT | 6 ELEMENT | 8 ELEMENT | 12 ELEMENT | 24 ELEMENT |
---|---|---|---|---|---|---|
Crush (Short Term) | N/100 mm | 1000 | 1000 | 1000 | 1000 | 1000 |
Strength member | FRP/Aramid | FRP/Aramid | FRP/Aramid | FRP/Aramid | FRP/Aramid | |
Storage Temperature | °C | -20~+60 | -20~+60 | -20~+60 | -20~+60 | -20~+60 |
Installation Temperature | °C | 0~+50 | 0~+50 | 0~+50 | 0~+50 | 0~+50 |
Operating Temperature | °C | -20~+60 | -20~+60 | -20~+60 | -20~+60 | -20~+60 |
Nominal Weight | kg/km | 46 | 63 | 86 | 139 | 159 |
Fiber count | n | 4 | 6 | 8 | 12 | 24 |
Nominal Outer Diameter | mm | 7.0 | 8.2 | 9.4 | 11.8 | 14.1 |
Maximum Tensile Load (installation) | N | 500 | 1000 | 1100 | 1400 | 1400 |
Maximum Tensile Load (installed) | N | 270 | 600 | 700 | 700 | 700 |
Minimum Bend Radius (installation) | mm | 140 | 160 | 190 | 240 | 280 |
Minimum Bend Radius (installed) | mm | 70 | 80 | 95 | 120 | 140 |
Fire Performance | CPR EuroClass | Eca | Eca | Eca | Eca | Eca |
Drum Length | km | 2 | 2 | 2 | 2 | 2 |
Other diameters are available upon request.
PART NUMBER (PN) |
DESCRIPTION | PHASING OUT PN |
---|---|---|
C1BC*G2BGZ | AFL Hyperscale **f OM1 62.5/125 Int Breakout Cable 2.0mm 900µm TB Aramid LSZH Orange CPR | OM1BO**JCOR |
C2BC*G2BGZ | AFL Hyperscale **f OM2 50/125 Int Breakout Cable 2.0mm 900µm TB Aramid LSZH Orange CPR | OM2BO**JCOR |
C3BC*GCBGZ | AFL Hyperscale **f OM3 50/125 Int Breakout Cable 2.0mm 900µm TB Aramid LSZH Aqua CPR | OM3BO**JCAQ |
C4BC*GCBGZ | AFL Hyperscale **f OM4 50/125 Int Breakout Cable 2.0mm 900µm TB Aramid LSZH Aqua CPR | OM4BO**JCAQ |
C4BC*GDBGZ | AFL Hyperscale **f OM4 50/125 Int Breakout Cable 2.0mm 900µm TB Aramid LSZH Erika Violet CPR | OM4BO**JCEV |
C9BC*G9BGZ | AFL Hyperscale **f G.652D 9/125 Int Breakout Cable 2.0mm 900µm TB Aramid LSZH Yellow CPR | OS1BO**JCYE |
C7BC*G9BGZ | AFL Hyperscale **f G.657A1 9/125 Int Breakout Cable 2.0mm 900µm TB Aramid LSZH Yellow CPR | 7A1BO**JCYE |
Where * is the cable fiber count code for the part number and ** is the cable fiber count for the description
*Fiber count code | ** Cable fiber count |
---|---|
4 | 04 |
6 | 06 |
8 | 08 |
A | 12 |
B | 16 |
C | 24 |
The following table represents colors available, on request, for the cable jacket.
Color name | Blue | Orange | Green | Red | Yellow | Purple | Aqua | Erika Violet |
---|---|---|---|---|---|---|---|---|
Color Code | 1 | 2 | 3 | 7 | 9 | A | C | D |
***Color |
***Please note that these colors are for guidance only and may display differently depending on your screen or printer.
To order a four fiber single mode cable with red jacket replace G9 in the part number with G7 and change Yellow in the description to Red.
For example –
C7BC4G7BGZ AFL Hyperscale 04f G.657A1 9/125 Int Breakout Cable 2.0mm 900µm TB Aramid LSZH Red CPR